Real-Time Knee Angle Prediction Using EMG and Kinematic Data with an Attention-Based CNN-LSTM Network and Transfer Learning Across Multiple Datasets

Mollahossein, Mojtaba, Vossoughi, Gholamreza, Rohban, Mohammad Hossein

arXiv.org Artificial Intelligence 

Electromyography (EMG) signals are widely used for predicting body joint angles through machine learning (ML) and deep learni ng (DL) methods. However, these approaches often face challenges such as limited real - time applicability, non - representative test c onditions, and the need for large datasets to achieve optimal performance. This paper presents a transfer - learning framework for knee joint angle prediction that requires only a few gait cycles from new subjects. Three datasets - Georgia Tech, the Universi ty of California Irvine (UCI), and the Sharif Mechatronic Lab Exoskeleton (SMLE) - containing four EMG channels relevant to knee motion were utilized. A lightweight attention - based CNN - LSTM model was developed and pre - trained on the Georgia Tech dataset, t hen transferred to the UCI and SMLE datasets. The proposed model achieved Normalized Mean Absolute Errors (NMAE) of 6.8 percent and 13.7 percent for one - step and 50 - step predictions on abnormal subjects using EMG inputs alone. Incorporating historical knee angles reduced the NMAE to 3.1 percent and 3.5 percent for normal subjects, and to 2.8 percent and 7.5 percent for abnormal subjects. When f urther adapted to the SMLE exoskeleton with EMG, kinematic, and interaction force inputs, the model achieved 1.09 p ercent and 3.1 percent NMAE for one - and 50 - step predictions, respectively. These results demonstrate robust performance and strong generalization for both short - and long - term rehabilitation scenarios . Keywords: EMG, Transfer Learning, Knee Angle Prediction, Attention Mechanism, Rehabilitation, Exoskeleton . 1 - Introduction Electromyography (EMG) measures electrical signals generated by contracting muscle fibers, reflecting neuromuscular activity. EMG is typically measured using electrodes placed on the skin's surface (surface Electromyography (sEMG)). Alternatively, electrodes may be inserted into the muscle tissue [2] . The frequency range of EMG signals is generally reported to be from 6 to 500 Hz, with most power concentrated between 20 and 250 Hz [3] . Analyzing EMG signals provides valuable information about muscle activation patterns, coordination, and fatigue levels.

Duplicate Docs Excel Report

Title
None found

Similar Docs  Excel Report  more

TitleSimilaritySource
None found