Goto

Collaborating Authors

 pubmed pmid


Accelerated MR Elastography Using Learned Neural Network Representation

arXiv.org Artificial Intelligence

To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset. We first framed the deep neural network representation as a nonlinear extension of the linear subspace model, then used it to represent and reconstruct MRE image repetitions from undersampled k-space data. The network weights were learned using a multi-level k-space consistent loss. To further enhance reconstruction quality, phase-contrast specific magnitude and phase priors were incorporated, including the similarity of anatomical structures and smoothness of wave-induced harmonic displacement. Experiments were conducted using both 3D gradient-echo spiral and multi-slice spin-echo spiral MRE datasets. Compared to the conventional linear subspace-based approaches, the nonlinear network representation method was able to produce superior image reconstruction with suppressed noise and artifacts from a single in-plane spiral arm per MRE repetition (e.g., 2mm isotropic resolution in 1 min with a total R=10), yielding comparable stiffness estimation to the fully sampled data. This work demonstrated the feasibility of using deep network representations to model and reconstruct MRE images from highly-undersampled data, a nonlinear extension of the subspace-based approaches.


DXA-Derived Skeletal Phenotypes and Hip Fracture Risk: A Backdoor-Adjusted Causal Analysis

arXiv.org Artificial Intelligence

Purpose: To compare dual-energy X-ray absorptiometry (DXA)-derived hip skeletal phenotypes in relation to hip fracture risk using prespecified confounder adjustment and to assess whether phenotypes ranked by their backdoor-adjusted average treatment effects (ATEs) improve risk stratification. Methods: We analyzed 21,098 UK Biobank participants with linked health records, hip DXA-derived skeletal measures, and prespecified covariates. Sixteen phenotypes spanning bone mineral content (BMC), bone mineral density (BMD), and T-score across hip-related regions were evaluated. Confounder selection was guided by a prespecified directed acyclic graph (DAG). Backdoor-adjusted ATEs were estimated on the absolute risk-difference scale per standard deviation (SD) increase. Effect heterogeneity was evaluated for total femur BMD, and downstream prediction was assessed using clinical variables combined with phenotypes ranked by ATE magnitude. Results: Among 21,098 participants, 115 had hip fractures. All 16 phenotypes showed negative backdoor-adjusted ATEs per SD increase. The largest ATEs were observed for total femur BMC and total femur BMD, each with a risk difference of -0.0047, corresponding to approximately 4.7 fewer hip fractures per 1,000 participants per SD higher phenotype value. Conditional effects of total femur BMD were stronger among older participants and those with lower BMI. In prediction, clinical variables plus the top 11 ATE-ranked phenotypes achieved higher AUC than FRAX with femoral neck BMD (0.842 vs. 0.709), with higher sensitivity (0.748 vs. 0.443) and similar specificity (0.793 vs. 0.777). Conclusion: DXA-derived hip skeletal phenotypes differed in their backdoor-adjusted ATEs. Phenotype-level causal evaluation may help identify informative DXA measures for risk stratification.


User Involvement in Robotic Wheelchair Development: A Decade of Limited Progress

arXiv.org Artificial Intelligence

Robotic wheelchairs (RWs) offer significant potential to enhance autonomy and participation for people with mobility impairments, yet many systems have failed to achieve sustained real-world adoption. This narrative literature review examined the extent and quality of end-user involvement in RW design, development, and evaluation over the past decade (2015--2025), assessed against core principles shared by major user-involvement approaches (e.g., user-/human-centered design, participatory/co-design, and inclusive design). The findings indicate that user involvement remains limited and is predominantly concentrated in late-stage evaluation rather than in early requirements definition or iterative co-design. Of the 399 records screened, only 23 studies (about 6%) met the inclusion criteria of verifiable end-user involvement, and many relied on small samples, often around ten participants, with limited justification for sample size selection, proxy users, laboratory-based validation, and non-standardized feedback methods. Research teams were largely engineering-dominated (about 89%) and geographically concentrated in high-income countries. Despite strong evidence that sustained user engagement improves usability and adoption in assistive technology, its systematic implementation in RW research remains rare. Advancing the field requires embedding participatory methodologies throughout the design lifecycle and addressing systemic barriers that constrain meaningful user involvement.


Clinically Meaningful Explainability for NeuroAI: An ethical, technical, and clinical perspective

arXiv.org Artificial Intelligence

While explainable AI (XAI) is often heralded as a means to enhance transparency and trustworthiness in closed-loop neurotechnology for psychiatric and neurological conditions, its real-world prevalence remains low. Moreover, empirical evidence suggests that the type of explanations provided by current XAI methods often fails to align with clinicians' end-user needs. In this viewpoint, we argue that clinically meaningful explainability (CME) is essential for AI-enabled closed-loop medical neurotechnology and must be addressed from an ethical, technical, and clinical perspective. Instead of exhaustive technical detail, clinicians prioritize clinically relevant, actionable explanations, such as clear representations of input-output relationships and feature importance. Full technical transparency, although theoretically desirable, often proves irrelevant or even overwhelming in practice, as it may lead to informational overload. Therefore, we advocate for CME in the neurotechnology domain: prioritizing actionable clarity over technical completeness and designing interface visualizations that intuitively map AI outputs and key features into clinically meaningful formats. To this end, we introduce a reference architecture called NeuroXplain, which translates CME into actionable technical design recommendations for any future neurostimulation device. Our aim is to inform stakeholders working in neurotechnology and regulatory framework development to ensure that explainability fulfills the right needs for the right stakeholders and ultimately leads to better patient treatment and care.


Towards Automated Diagnosis of Inherited Arrhythmias: Combined Arrhythmia Classification Using Lead-Aware Spatial Attention Networks

arXiv.org Artificial Intelligence

Arrhythmogenic right ventricular cardiomyopathy (ARVC) and long QT syndrome (LQTS) are inherited arrhythmia syndromes associated with sudden cardiac death. Deep learning shows promise for ECG interpretation, but multi-class inherited arrhythmia classification with clinically grounded interpretability remains underdeveloped. Our objective was to develop and validate a lead-aware deep learning framework for multi-class (ARVC vs LQTS vs control) and binary inherited arrhythmia classification, and to determine optimal strategies for integrating ECG foundation models within arrhythmia screening tools. We assembled a 13-center Canadian cohort (645 patients; 1,344 ECGs). We evaluated four ECG foundation models using three transfer learning approaches: linear probing, fine-tuning, and combined strategies. We developed lead-aware spatial attention networks (LASAN) and assessed integration strategies combining LASAN with foundation models. Performance was compared against the established foundation model baselines. Lead-group masking quantified disease-specific lead dependence. Fine-tuning outperformed linear probing and combined strategies across all foundation models (mean macro-AUROC 0.904 vs 0.825). The best lead-aware integrations achieved near-ceiling performance (HuBERT-ECG hybrid: macro-AUROC 0.990; ARVC vs control AUROC 0.999; LQTS vs control AUROC 0.994). Lead masking demonstrated physiologic plausibility: V1-V3 were most critical for ARVC detection (4.54% AUROC reduction), while lateral leads were preferentially important for LQTS (2.60% drop). Lead-aware architectures achieved state-of-the-art performance for inherited arrhythmia classification, outperforming all existing published models on both binary and multi-class tasks while demonstrating clinically aligned lead dependence. These findings support potential utility for automated ECG screening pending validation.


Diffusion Transformer-based Universal Dose Denoising for Pencil Beam Scanning Proton Therapy

arXiv.org Artificial Intelligence

Purpose: Intensity-modulated proton therapy (IMPT) offers precise tumor coverage while sparing organs at risk (OARs) in head and neck (H&N) cancer. However, its sensitivity to anatomical changes requires frequent adaptation through online adaptive radiation therapy (oART), which depends on fast, accurate dose calculation via Monte Carlo (MC) simulations. Reducing particle count accelerates MC but degrades accuracy. To address this, denoising low-statistics MC dose maps is proposed to enable fast, high-quality dose generation. Methods: We developed a diffusion transformer-based denoising framework. IMPT plans and 3D CT images from 80 H&N patients were used to generate noisy and high-statistics dose maps using MCsquare (1 min and 10 min per plan, respectively). Data were standardized into uniform chunks with zero-padding, normalized, and transformed into quasi-Gaussian distributions. Testing was done on 10 H&N, 10 lung, 10 breast, and 10 prostate cancer cases, preprocessed identically. The model was trained with noisy dose maps and CT images as input and high-statistics dose maps as ground truth, using a combined loss of mean square error (MSE), residual loss, and regional MAE (focusing on top/bottom 10% dose voxels). Performance was assessed via MAE, 3D Gamma passing rate, and DVH indices. Results: The model achieved MAEs of 0.195 (H&N), 0.120 (lung), 0.172 (breast), and 0.376 Gy[RBE] (prostate). 3D Gamma passing rates exceeded 92% (3%/2mm) across all sites. DVH indices for clinical target volumes (CTVs) and OARs closely matched the ground truth. Conclusion: A diffusion transformer-based denoising framework was developed and, though trained only on H&N data, generalizes well across multiple disease sites.


Implicit neural representation for free-breathing MR fingerprinting (INR-MRF): co-registered 3D whole-liver water T1, water T2, proton density fat fraction, and R2* mapping

arXiv.org Artificial Intelligence

Purpose: To develop an MRI technique for free-breathing 3D whole-liver quantification of water T1, water T2, proton density fat fraction (PDFF), R2*. Methods: An Eight-echo spoiled gradient echo pulse sequence with spiral readout was developed by interleaving inversion recovery and T2 magnetization preparation. We propose a neural network based on a 4D and a 3D implicit neural representation (INR) which simultaneously learns the motion deformation fields and the static reference frame MRI subspace images respectively. Water and fat singular images were separated during network training, with no need of performing retrospective water-fat separation. T1, T2, R2* and proton density fat fraction (PDFF) produced by the proposed method were validated in vivo on 10 healthy subjects, using quantitative maps generated from conventional scans as reference. Results: Our results showed minimal bias and narrow 95% limits of agreement on T1, T2, R2* and PDFF values in the liver compared to conventional breath-holding scans. Conclusions: INR-MRF enabled co-registered 3D whole liver T1, T2, R2* and PDFF mapping in a single free-breathing scan.


Characterization of Human Balance through a Reinforcement Learning-based Muscle Controller

arXiv.org Artificial Intelligence

Abstract: Balance assessment during physical rehabilitation often relies on rubricoriented battery tests to score a patient's physical capabilities, leading to subjectivity. While some objective balance assessments exist, they are often limited to tracking the center of pressure (COP), which does not fully capture the whole-body postural stability. This study explores the use of the center of mass (COM) state space and presents a promising avenue for monitoring the balance capabilities in humans. We employ a musculoskeletal model integrated with a balance controller, trained through reinforcement learning (RL), to investigate balancing capabilities. The RL framework consists of two interconnected neural networks governing balance recovery and muscle coordination respectively, trained using Proximal Policy Optimization (PPO) with reference state initialization, early termination, and multiple training strategies. By exploring recovery from random initial COM states (position and velocity) space for a trained controller, we obtain the final BR enclosing successful balance recovery trajectories. Comparing the BRs with analytical postural stability limits from a linear inverted pendulum model, we observe a similar trend in successful COM states but more limited ranges in the recoverable areas. We further investigate the effect of muscle weakness and neural excitation delay on the BRs, revealing reduced balancing capability in different regions. Overall, our approach of learning muscular balance controllers presents a promising new method for establishing balance recovery limits and objectively assessing balance capability in bipedal systems, particularly in humans. Keywords: Balance, Reinforcement Learning, Musculoskeletal Modeling, Bipedal Systems, Motor Disorders 1. Introduction Falls and subsequent injuries pose a significant health risk for the elderly and mobility-impaired populations. Poor balancing capabilities are the leading cause of falls in the elderly population, which reduces the overall quality of life of aging patients [1-3]. The injuries sustained by these patients can range from lower-body fractures, particularly in the hip, to head injuries, with falls being the leading cause of traumatic brain injuries [4]. Therefore, effective balance assessment and rehabilitation are critical components not only to health monitoring and injury prevention in mobility-impaired individuals, but also to the diagnoses of other serious underlying medical conditions. Since balance is maintained through a complicated network of physiological systems in the body, it is difficult to pinpoint a single origin causing deficiencies in patients and to assess balance through simple isolated measures. In most clinical environments, balance assessment is performed as a battery of balance exercises designed to evaluate the patient's ability to perform selected tasks.


Review of Machine-Learning Methods for RNA Secondary Structure Prediction

arXiv.org Machine Learning

Secondary structure plays an important role in determining the function of non-coding RNAs. Hence, identifying RNA secondary structures is of great value to research. Computational prediction is a mainstream approach for predicting RNA secondary structure. Unfortunately, even though new methods have been proposed over the past 40 years, the performance of computational prediction methods has stagnated in the last decade. Recently, with the increasing availability of RNA structure data, new methods based on machine-learning technologies, especially deep learning, have alleviated the issue. In this review, we provide a comprehensive overview of RNA secondary structure prediction methods based on machine-learning technologies and a tabularized summary of the most important methods in this field. The current pending issues in the field of RNA secondary structure prediction and future trends are also discussed.