Oceania
Examples of learning curves from a modified VC-formalism
Kowalczyk, Adam, Szymanski, Jacek, Bartlett, Peter L., Williamson, Robert C.
We examine the issue of evaluation of model specific parameters in a modified VC-formalism. Two examples are analyzed: the 2-dimensional homogeneous perceptron and the I-dimensional higher order neuron. Both models are solved theoretically, and their learning curves are compared against true learning curves. It is shown that the formalism has the potential to generate a variety of learning curves, including ones displaying ''phase transitions."
Examples of learning curves from a modified VC-formalism
Kowalczyk, Adam, Szymanski, Jacek, Bartlett, Peter L., Williamson, Robert C.
We examine the issue of evaluation of model specific parameters in a modified VC-formalism. Two examples are analyzed: the 2-dimensional homogeneous perceptron and the I-dimensional higher order neuron. Both models are solved theoretically, and their learning curves are compared against true learning curves. It is shown that the formalism has the potential to generate a variety of learning curves, including ones displaying ''phase transitions."
The Gamma MLP for Speech Phoneme Recognition
Lawrence, Steve, Tsoi, Ah Chung, Back, Andrew D.
We define a Gamma multi-layer perceptron (MLP) as an MLP with the usual synaptic weights replaced by gamma filters (as proposed by de Vries and Principe (de Vries and Principe, 1992)) and associated gain terms throughout all layers. We derive gradient descent update equations and apply the model to the recognition of speech phonemes. We find that both the inclusion of gamma filters in all layers, and the inclusion of synaptic gains, improves the performance of the Gamma MLP. We compare the Gamma MLP with TDNN, Back-Tsoi FIR MLP, and Back-Tsoi I1R MLP architectures, and a local approximation scheme. We find that the Gamma MLP results in an substantial reduction in error rates.
A Novel Channel Selection System in Cochlear Implants Using Artificial Neural Network
Jabri, Marwan A., Wang, Raymond J.
A cochlear implant is a device used to provide the sensation of sound to those who are profoundly deaf by means of electrical stimulation of residual auditory neurons. It generally consists of a directional microphone, a wearable speech processor, a headset transmitter and an implanted receiver-stimulator module with an electrode A Novel Channel Selection System in Cochlear Implants 911 array which all together provide an electrical representation of the speech signal to the residual nerve fibres of the peripheral auditory system (Clark et ai, 1990).
The Gamma MLP for Speech Phoneme Recognition
Lawrence, Steve, Tsoi, Ah Chung, Back, Andrew D.
Department of Electrical and Computer Engineering University of Queensland St. Lucia Qld 4072 Australia Abstract We define a Gamma multi-layer perceptron (MLP) as an MLP with the usual synaptic weights replaced by gamma filters (as proposed byde Vries and Principe (de Vries and Principe, 1992)) and associated gain terms throughout all layers. We derive gradient descent update equations and apply the model to the recognition of speech phonemes. We find that both the inclusion of gamma filters in all layers, and the inclusion of synaptic gains, improves the performance of the Gamma MLP. We compare the Gamma MLP with TDNN, Back-Tsoi FIR MLP, and Back-Tsoi I1R MLP architectures, and a local approximation scheme. We find that the Gamma MLP results in an substantial reduction in error rates. 1 INTRODUCTION 1.1 THE GAMMA FILTER Infinite Impulse Response (I1R) filters have a significant advantage over Finite Impulse Response(FIR) filters in signal processing: the length of the impulse response is uncoupled from the number of filter parameters.
A Novel Channel Selection System in Cochlear Implants Using Artificial Neural Network
Jabri, Marwan A., Wang, Raymond J.
A cochlear implant is a device used to provide the sensation of sound to those who are profoundly deaf by means of electrical stimulation of residual auditory neurons. It generally consists of a directional microphone, a wearable speech processor, a headset transmitter and an implanted receiver-stimulator module with an electrode A Novel Channel Selection System in Cochlear Implants 911 array which all together provide an electrical representation of the speech signal to the residual nerve fibres of the peripheral auditory system (Clark et ai, 1990).
Examples of learning curves from a modified VC-formalism
Kowalczyk, Adam, Szymanski, Jacek, Bartlett, Peter L., Williamson, Robert C.
We examine the issue of evaluation of model specific parameters in a modified VC-formalism. Two examples are analyzed: the 2-dimensional homogeneous perceptron and the I-dimensional higher order neuron. Both models are solved theoretically, and their learning curves are compared againsttrue learning curves. It is shown that the formalism has the potential to generate a variety of learning curves, including ones displaying ''phase transitions."